KeyTec® TR-FRET GDP loaded KRAS[G12D]/SOS1 Binding Assay kit

    TR-FRET Assay for measurement of the interaction between KRAS[G12D] and SOS1 proteins

    • Easy to Use: A homogeneous assay - just follow the 'add-incubate-measure' process • High Accuracy: Utilizes GDP-loaded KRAS[G12D] protein, aligning more closely with physiological conditions. • High S/B: The kit provides a superior window
Size: 1,000 tests10,000 tests
Price: $ 2,000
CAT.: A1090001S
Delivery: Available in Stock
KeyTec® TR-FRET GDP loaded KRAS[G12D]/SOS1 Binding Assay kit

    TR-FRET Assay for measurement of the interaction between KRAS[G12D] and SOS1 proteins

    • Easy to Use: A homogeneous assay - just follow the 'add-incubate-measure' process • High Accuracy: Utilizes GDP-loaded KRAS[G12D] protein, aligning more closely with physiological conditions. • High S/B: The kit provides a superior window
Size: 1,000 tests10,000 tests
CAT.: A1090001S
Delivery: Available in Stock
Price: $ 2,000
Overview
The KeyTec® TR-FRET GDP loaded KRAS[G12D]/SOS1 Binding Assay kit is designed for measurement of the interaction between KRAS[G12D] and SOS1 proteins. It is based on sandwich immunoassay model and utilizes TR-FRET technology, known for its ease of use, homogeneity (no wash), low background, high sensitivity, high accuracy. The detection principle is based on TR-FRET technology. The Tag2-SOS1 protein binds to the donor (KeyTec® TR-FRET mAb anti-HIS-Solar Eu), and the Tag1-KRAS[G12D] [GDP loaded] protein binds to the acceptor (mAb anti-Tag1–LA). When KRAS[G12D] [GDP loaded] interacts with SOS1, the donor molecule is brought into proximity with the acceptor molecule. Excitation of the donor will result in the generation of the TR-FRET signal at 665 nm, proportional to the extent of protein interaction. Blocking this interaction with any compound, peptide, or antibody will reduce the TR-FRET signal.
Performance
•The inhibitory effects of small molecules
•The results of GTP EC50
•The results of GDP IC50
Protocols
Protocol_A1090001_KeyTec® TR-FRET GDP loaded KRAS[G12D] ∕ SOS1 Binding Assay kit_VKEYBIO-01-2024.pdf
Components
CAT.
Description
Size
A1090001S
KeyTec® TR-FRET GDP loaded KRAS[G12D]/SOS1 Binding Assay kit
1,000 tests
The tests are sufficient in a 384-well microplate assay format, with 20 μL per well. • 1 × 45 µL Tag1-KRAS[G12D] [ GDP loaded ] (100X) • 1 × 45 µL Tag2-SOS1 (100X) • 1 × 50 µL mAb anti-Tag2–Solar Eu (100X) • 1 × 50 µL mAb anti-Tag1–LA (100X) • 1 × 45 µL GTP (100X,2.5 mM) • 1 × 50 mL Binding Assay Diluent Buffer • 1 × 30 mL Solar Eu Detection Buffer
Notices
Certificate of Analysis
Limitations
Storage Conditions
For research use only

-60℃ or blow

Related Products
Overview
The KeyTec® TR-FRET GDP loaded KRAS[G12D]/SOS1 Binding Assay kit is designed for measurement of the interaction between KRAS[G12D] and SOS1 proteins. It is based on sandwich immunoassay model and utilizes TR-FRET technology, known for its ease of use, homogeneity (no wash), low background, high sensitivity, high accuracy. The detection principle is based on TR-FRET technology. The Tag2-SOS1 protein binds to the donor (KeyTec® TR-FRET mAb anti-HIS-Solar Eu), and the Tag1-KRAS[G12D] [GDP loaded] protein binds to the acceptor (mAb anti-Tag1–LA). When KRAS[G12D] [GDP loaded] interacts with SOS1, the donor molecule is brought into proximity with the acceptor molecule. Excitation of the donor will result in the generation of the TR-FRET signal at 665 nm, proportional to the extent of protein interaction. Blocking this interaction with any compound, peptide, or antibody will reduce the TR-FRET signal.
Performance
•The inhibitory effects of small molecules
•The results of GTP EC50
•The results of GDP IC50
Protocols
Protocol_A1090001_KeyTec® TR-FRET GDP loaded KRAS[G12D] ∕ SOS1 Binding Assay kit_VKEYBIO-01-2024.pdf
Components
CAT.
Description
Size
A1090001S
KeyTec® TR-FRET GDP loaded KRAS[G12D]/SOS1 Binding Assay kit
1,000 tests
The tests are sufficient in a 384-well microplate assay format, with 20 μL per well. • 1 × 45 µL Tag1-KRAS[G12D] [ GDP loaded ] (100X) • 1 × 45 µL Tag2-SOS1 (100X) • 1 × 50 µL mAb anti-Tag2–Solar Eu (100X) • 1 × 50 µL mAb anti-Tag1–LA (100X) • 1 × 45 µL GTP (100X,2.5 mM) • 1 × 50 mL Binding Assay Diluent Buffer • 1 × 30 mL Solar Eu Detection Buffer
Notices
Certificate of Analysis
Limitations
Storage Conditions
For research use only

-60℃ or blow

Related Products

Shanghai VKEY Biotechnologies Co.,Ltd.

Tel: 021-5835-6939

Email: business@vkeybio.com

Official WeChat Account

沪ICP备2021012748号

Shanghai VKEY Biotechnologies Co.,Ltd.

Tel: 021-5835-6939

Email: business@vkeybio.com

Official WeChat Account

沪ICP备2021012748号
WeChat

Sales Assistant:

Technical-Support:

WeChat Official Account:

Contact Us

Technical Support Email: technical-support@vkeybio.com

BD Email: business@vkeybio.com

Tel:
021-5835-6939

Cooperation