Overview
The KeyTec® TR-FRET Human IgG detection kit is designed for quantitative measurement of human IgG in supernatant. It is based on sandwich immunoassay model and utilizes TR-FRET technology, known for its ease of use, homogeneity (no wash), low background, high sensitivity, robustness.
The screening principle is based on TR-FRET technology. The mAb anti-hFc antibody is labeled with KeyTec® TR-FRET Solar Eu and pAb anti-hFab antibody is labeled with KeyTec® TR-FRET LA, when mAb anti-hFc-Solar Eu and pAb anti-hFab-LA bind to Human IgG, the donor molecule is brought into proximity with the acceptor molecule. Excitation of the donor will result in the generation of the TR-FRET signal at 665 nm, proportional to the concentration of Human IgG.
Performance
• Standard Curve
• Quantitative Range:2 ng/mL – 900 ng/mL
• Incubation Condition:Incubate at room temperature for 2 hours
Protocols
Components
CAT. |
Description |
Size |
A1040001S |
KeyTec® TR-FRET Human IgG Detection kit |
1,000 tests |
The tests are sufficient in a 384-well microplate assay format, with 20 μL per well.
• 1 × 100 µL mAb anti-hFc - Solar Eu (50X)
• 1 × 100 µL mAb pAb anti-hFab - LA (50X)
• 1 × 150 µL Human IgG Standard (5 µg/mL)
• 1 × 30 mL Biotherapeutics Diluent Buffer
• 1 × 10 mL Biotherapeutics Detection Buffer |
Notices
Certificate of Analysis |
Limitations |
Storage Conditions |
LOT.
|
For research use only |
-60℃ or below
|
Overview
The KeyTec® TR-FRET Human IgG detection kit is designed for quantitative measurement of human IgG in supernatant. It is based on sandwich immunoassay model and utilizes TR-FRET technology, known for its ease of use, homogeneity (no wash), low background, high sensitivity, robustness.
The screening principle is based on TR-FRET technology. The mAb anti-hFc antibody is labeled with KeyTec® TR-FRET Solar Eu and pAb anti-hFab antibody is labeled with KeyTec® TR-FRET LA, when mAb anti-hFc-Solar Eu and pAb anti-hFab-LA bind to Human IgG, the donor molecule is brought into proximity with the acceptor molecule. Excitation of the donor will result in the generation of the TR-FRET signal at 665 nm, proportional to the concentration of Human IgG.
Performance
• Standard Curve
• Quantitative Range:2 ng/mL – 900 ng/mL
• Incubation Condition:Incubate at room temperature for 2 hours
Protocols
Components
CAT. |
Description |
Size |
A1040001L |
KeyTec® TR-FRET Human IgG Detection kit |
10,000 tests |
The tests are sufficient in a 384-well microplate assay format, with 20 μL per well.
• 1 × 1,000 µL mAb anti-hFc - Solar Eu (50X)
• 1 × 1,000 µL mAb pAb anti-hFab - LA (50X)
• 2 × 150 µL Human IgG Standard (5 µg/mL)
• 1 × 200 mL Biotherapeutics Diluent Buffer
• 1 × 100 mL Biotherapeutics Detection Buffer |
Notices
Certificate of Analysis |
Limitations |
Storage Conditions |
LOT.
|
For research use only |
-60℃ or below
|